Whoever constructs a building
Owners of existing residential and non-residential buildings heated to at least 19 degrees Celsius for at least four months a year
Existing buildings where external building elements are renewed, replaced or installed for the first time
Owners of existing buildings or building networks replacing the heating system
Existing buildings with a gas, heating oil or LPG heating system newly installed after 29 July 2026
Non-residential buildings with a system rated output above 70 kilowatts
Operators of heating, cooling and ventilation systems and hot water supply systems
Heat pumps in buildings with at least six dwellings or self-contained units, commissioned after 31 December 2023, without remote monitoring and without a maintenance contract
Water-based heating systems in buildings with at least six dwellings or self-contained units
Water-based heating systems after installation of a heating system in buildings with at least six dwellings
Operators of air conditioning systems and combined air conditioning and ventilation systems with more than 12 and up to 70 kilowatts of cooling output
Operators of air conditioning, combined air conditioning and ventilation and ventilation systems above 70 kilowatts
Developers and owners on construction, alteration, sale and letting
Sellers, landlords, lessors, financial lessors and estate agents
Developers and owners of buildings to be constructed and of altered buildings
Companies carrying out works on or in existing buildings in the course of business
Inspecting persons
Building owners holding a contractor declaration
Buildings where distribution equipment, air conditioning systems, ventilation systems or pipes are installed or replaced
Buildings to be constructed, except buildings serving national and alliance defence
New non-residential buildings with more than 250 square metres of useful floor area
Existing non-residential buildings above 500 square metres of useful floor area undergoing alterations of external building elements
Existing public non-residential buildings above 2 000 square metres of useful floor area
Existing public non-residential buildings above 750 square metres of useful floor area
New residential buildings and new roofed car parks
Existing public non-residential buildings above 250 square metres of useful floor area
Owners of existing non-residential buildings built before 1996 without biomass, heat pump or district heating
Owners of existing non-residential buildings
New buildings above 1 000 square metres of useful floor area
Complexity (0–5)
Business functions
Communications
Compliance
Executive
Finance
Human Resources
Legal
Operations
Other
Procurement
Product
Sales
Sustainability
Description (English)
Owners of a residential building and owners of a non-residential building heated by its intended use to at least 19 degrees Celsius for at least four months a year must ensure that top storey ceilings not meeting the minimum thermal insulation requirements of DIN 4108-2 are insulated so that the thermal transmittance does not exceed 0.24 watts per square metre and kelvin. The obligation is deemed met where the roof above is insulated accordingly instead, or already meets the minimum thermal insulation requirements. Variants: where the insulation is placed within ceiling cavities and its thickness is technically limited, the requirement is deemed met if the greatest possible thickness under the recognised rules of technology is installed, with a design thermal conductivity of 0.035 W/(m·K), or 0.045 W/(m·K) for blown-in insulation or insulation from renewable raw materials. The same applies to insulation between rafters. For a residential building with no more than two dwellings, one of which the owner occupied on 1 February 2002, the duty falls on the new owner only after a change of ownership, with a two-year deadline; it lapses where the expenditure cannot be recovered within a reasonable period. Further references: Section 35(1) to (4), Section 102.
Description (German)
Eigentümer eines Wohngebäudes sowie Eigentümer eines Nichtwohngebäudes, das nach seiner Zweckbestimmung jährlich mindestens vier Monate auf Innentemperaturen von mindestens 19 Grad Celsius beheizt wird, müssen dafür sorgen, dass oberste Geschossdecken, die nicht den Anforderungen an den Mindestwärmeschutz nach DIN 4108-2 genügen, so gedämmt sind, dass der Wärmedurchgangskoeffizient 0,24 Watt pro Quadratmeter und Kelvin nicht überschreitet. Die Pflicht gilt als erfüllt, wenn anstelle der obersten Geschossdecke das darüber liegende Dach entsprechend gedämmt ist oder den Anforderungen an den Mindestwärmeschutz genügt. Varianten: Wird die Dämmung in Deckenzwischenräumen ausgeführt und ist die Dämmschichtdicke technisch begrenzt, gilt die Anforderung als erfüllt, wenn die nach anerkannten Regeln der Technik höchstmögliche Dämmschichtdicke eingebaut wird; dabei ist ein Bemessungswert der Wärmeleitfähigkeit von 0,035 W/(m·K) einzuhalten, bei eingeblasenen Dämmstoffen oder Dämmstoffen aus nachwachsenden Rohstoffen 0,045 W/(m·K). Entsprechendes gilt für eine Zwischensparrendämmung. Bei einem Wohngebäude mit höchstens zwei Wohnungen, von denen der Eigentümer eine am 1. Februar 2002 selbst bewohnt hat, trifft die Pflicht erst den neuen Eigentümer nach einem Eigentümerwechsel, mit einer Frist von zwei Jahren; sie entfällt, soweit die Aufwendungen sich nicht innerhalb angemessener Frist erwirtschaften lassen. Weitere Fundstellen: § 35 Absätze 1 bis 4, § 102.
Affected products/services (English)
Top storey ceilings and the roofs above them in the company’s existing buildings.
Affected products/services (German)
Oberste Geschossdecken und darüber liegende Dächer der bestehenden Gebäude des Unternehmens.
Checking responsibility (English)
Building owner; operationally real estate management.
Checking responsibility (German)
Gebäudeeigentümer; operativ das Immobilienmanagement.
Check method (English)
Evidence of the thermal transmittance per building, usually through the contractor declaration under Section 96(1), point 2.
Check method (German)
Nachweis des Wärmedurchgangskoeffizienten je Gebäude, in der Regel über die Unternehmererklärung nach § 96 Absatz 1 Nummer 2.