Whoever constructs a building
Owners of existing residential and non-residential buildings heated to at least 19 degrees Celsius for at least four months a year
Existing buildings where external building elements are renewed, replaced or installed for the first time
Owners of existing buildings or building networks replacing the heating system
Existing buildings with a gas, heating oil or LPG heating system newly installed after 29 July 2026
Non-residential buildings with a system rated output above 70 kilowatts
Operators of heating, cooling and ventilation systems and hot water supply systems
Heat pumps in buildings with at least six dwellings or self-contained units, commissioned after 31 December 2023, without remote monitoring and without a maintenance contract
Water-based heating systems in buildings with at least six dwellings or self-contained units
Water-based heating systems after installation of a heating system in buildings with at least six dwellings
Operators of air conditioning systems and combined air conditioning and ventilation systems with more than 12 and up to 70 kilowatts of cooling output
Operators of air conditioning, combined air conditioning and ventilation and ventilation systems above 70 kilowatts
Developers and owners on construction, alteration, sale and letting
Sellers, landlords, lessors, financial lessors and estate agents
Developers and owners of buildings to be constructed and of altered buildings
Companies carrying out works on or in existing buildings in the course of business
Inspecting persons
Building owners holding a contractor declaration
Buildings where distribution equipment, air conditioning systems, ventilation systems or pipes are installed or replaced
Buildings to be constructed, except buildings serving national and alliance defence
New non-residential buildings with more than 250 square metres of useful floor area
Existing non-residential buildings above 500 square metres of useful floor area undergoing alterations of external building elements
Existing public non-residential buildings above 2 000 square metres of useful floor area
Existing public non-residential buildings above 750 square metres of useful floor area
New residential buildings and new roofed car parks
Existing public non-residential buildings above 250 square metres of useful floor area
Owners of existing non-residential buildings built before 1996 without biomass, heat pump or district heating
Owners of existing non-residential buildings
New buildings above 1 000 square metres of useful floor area
Complexity (0–5)
Business functions
Communications
Compliance
Executive
Finance
Human Resources
Legal
Operations
Other
Procurement
Product
Sales
Sustainability
Description (English)
From 1 January 2027 Section 60a applies in a new version. Heat pumps commissioned after 31 December 2023 as a heating system in a building with at least six dwellings or other self-contained units, or for feeding a building network with at least six connected units, must undergo an operational check after a complete heating season and at the latest two years after commissioning, where the heat pump is operated for space heating and hot water. The exemption is new: the duty does not apply to heat pumps subject to remote monitoring or covered by a maintenance contract. Only heat pumps without remote monitoring and without a maintenance contract must be re-checked at least every five years. The former catalogue of check items is dropped; the operational check now covers the settings and components relevant to the operation, function and efficiency of the heat pump. The result and any need for optimisation must be recorded in writing; necessary optimisation measures must be carried out within one year. Further references: Section 60a(1) to (4) as in force from 1 January 2027, Section 108(1), points 8 and 10.
Description (German)
Ab dem 1. Januar 2027 gilt § 60a in neuer Fassung. Wärmepumpen, die nach dem 31. Dezember 2023 als Heizungsanlage in einem Gebäude mit mindestens sechs Wohnungen oder sonstigen selbständigen Nutzungseinheiten oder zur Einspeisung in ein Gebäudenetz mit mindestens sechs angeschlossenen Einheiten in Betrieb genommen werden, sind nach einer vollständigen Heizperiode, spätestens zwei Jahre nach Inbetriebnahme, einer Betriebsprüfung zu unterziehen, wenn der Betrieb der Wärmepumpe für Raumwärme und Warmwasser erfolgt. Neu ist die Ausnahme: Die Pflicht entfällt für Wärmepumpen, die einer Fernkontrolle unterliegen oder für die ein Wartungsvertrag besteht. Nur Wärmepumpen ohne Fernkontrolle und ohne Wartungsvertrag sind spätestens alle fünf Jahre erneut zu prüfen. Der bisherige Katalog der Prüfpunkte entfällt; die Betriebsprüfung umfasst nunmehr die Überprüfung der für Betrieb, Funktion und Effizienz der Wärmepumpe maßgeblichen Einstellungen und Komponenten. Das Ergebnis und der etwaige Optimierungsbedarf sind schriftlich festzuhalten; erforderliche Optimierungsmaßnahmen sind innerhalb eines Jahres durchzuführen. Weitere Fundstellen: § 60a Absätze 1 bis 4 in der ab 1. Januar 2027 geltenden Fassung, § 108 Absatz 1 Nummern 8 und 10.
Affected products/services (English)
Heat pumps in the company’s buildings with at least six dwellings or self-contained units.
Affected products/services (German)
Wärmepumpen in Gebäuden des Unternehmens mit mindestens sechs Wohnungen oder selbständigen Nutzungseinheiten.
Checking responsibility (English)
Operator of the system; the check itself is carried out by a qualified person.
Checking responsibility (German)
Betreiber der Anlage; die Prüfung selbst führt eine fachkundige Person durch.
Check method (English)
Reconciliation of the system inventory with the check records and their dates; due where the last record is more than five years old.
Check method (German)
Abgleich der Anlagenliste mit den Prüfprotokollen und deren Datum; fällig, wenn das letzte Protokoll älter als fünf Jahre ist.