Whoever constructs a building
Owners of existing residential and non-residential buildings heated to at least 19 degrees Celsius for at least four months a year
Existing buildings where external building elements are renewed, replaced or installed for the first time
Owners of existing buildings or building networks replacing the heating system
Existing buildings with a gas, heating oil or LPG heating system newly installed after 29 July 2026
Non-residential buildings with a system rated output above 70 kilowatts
Operators of heating, cooling and ventilation systems and hot water supply systems
Heat pumps in buildings with at least six dwellings or self-contained units, commissioned after 31 December 2023, without remote monitoring and without a maintenance contract
Water-based heating systems in buildings with at least six dwellings or self-contained units
Water-based heating systems after installation of a heating system in buildings with at least six dwellings
Operators of air conditioning systems and combined air conditioning and ventilation systems with more than 12 and up to 70 kilowatts of cooling output
Operators of air conditioning, combined air conditioning and ventilation and ventilation systems above 70 kilowatts
Developers and owners on construction, alteration, sale and letting
Sellers, landlords, lessors, financial lessors and estate agents
Developers and owners of buildings to be constructed and of altered buildings
Companies carrying out works on or in existing buildings in the course of business
Inspecting persons
Building owners holding a contractor declaration
Buildings where distribution equipment, air conditioning systems, ventilation systems or pipes are installed or replaced
Buildings to be constructed, except buildings serving national and alliance defence
New non-residential buildings with more than 250 square metres of useful floor area
Existing non-residential buildings above 500 square metres of useful floor area undergoing alterations of external building elements
Existing public non-residential buildings above 2 000 square metres of useful floor area
Existing public non-residential buildings above 750 square metres of useful floor area
New residential buildings and new roofed car parks
Existing public non-residential buildings above 250 square metres of useful floor area
Owners of existing non-residential buildings built before 1996 without biomass, heat pump or district heating
Owners of existing non-residential buildings
New buildings above 1 000 square metres of useful floor area
Complexity (0–5)
Business functions
Communications
Compliance
Executive
Finance
Human Resources
Legal
Operations
Other
Procurement
Product
Sales
Sustainability
Description (English)
From 1 January 2030 the owner of an existing non-residential building must ensure by suitable measures that the annual primary energy demand for heating, hot water, ventilation, cooling and built-in lighting does not exceed 3.5 times that of a reference building with the same geometry, useful floor area, orientation and use built to the technical reference design of Annex 2; a primary energy factor of 0.7 is always used for the reference building. The requirement is deemed to be met where the building was constructed on or after 1 January 1996, where the owner shows that a building constructed earlier was brought to the level of the 1994 Thermal Insulation Ordinance, where the heating system generates heat mainly from biomass or a heat pump, or where the building is supplied with district heat. It does not apply where compliance is technically impossible or economically unreasonable or conflicts with other public-law provisions, nor to listed monuments or particularly protected building fabric, low-energy industrial plants, workshops and agricultural buildings, free-standing small buildings, buildings serving national and alliance defence, or buildings for which demolition, closure of the site, a change of use or a comprehensive refurbishment has been decided. Further references: Section 40(2) to (4) as in force from 1 January 2027, Annex 2.
Description (German)
Ab dem 1. Januar 2030 hat der Eigentümer eines bestehenden Nichtwohngebäudes mit geeigneten Maßnahmen dafür zu sorgen, dass der Jahres-Primärenergiebedarf für Heizung, Warmwasserbereitung, Lüftung, Kühlung und eingebaute Beleuchtung das 3,5fache des Jahres-Primärenergiebedarfs eines Referenzgebäudes nicht überschreitet, das die gleiche Geometrie, Nutzfläche, Ausrichtung und Nutzung aufweist und der technischen Referenzausführung der Anlage 2 entspricht; für das Referenzgebäude ist immer der Primärenergiefaktor 0,7 zu verwenden. Die Anforderung gilt als erfüllt, wenn das Nichtwohngebäude ab dem 1. Januar 1996 errichtet wurde, wenn der Eigentümer für ein älteres Gebäude das Anforderungsniveau der Wärmeschutzverordnung von 1994 nachweist, wenn die Heizungsanlage die Wärme überwiegend mit Biomasse oder einer Wärmepumpe erzeugt oder wenn das Gebäude mit Fernwärme versorgt wird. Sie ist nicht anzuwenden, soweit ihre Einhaltung technisch unmöglich oder wirtschaftlich unzumutbar ist oder anderen öffentlich-rechtlichen Vorschriften widerspricht, und ebenso wenig auf Baudenkmäler und besonders erhaltenswerte Bausubstanz, auf Industrieanlagen, Werkstätten und landwirtschaftliche Nutzgebäude mit niedrigem Energiebedarf, auf freistehende kleine Gebäude, auf Gebäude der Landes- und Bündnisverteidigung sowie auf Gebäude, für die Abriss, Betriebsaufgabe, Nutzungsänderung oder umfassende Sanierung feststehen. Weitere Fundstellen: § 40 Absätze 2 bis 4 in der ab 1. Januar 2027 geltenden Fassung, Anlage 2.
Affected products/services (English)
All existing non-residential buildings owned by the company, in particular stores, warehouses and administrative buildings.
Affected products/services (German)
Alle bestehenden Nichtwohngebäude im Eigentum des Unternehmens, insbesondere Filialen, Lager- und Verwaltungsgebäude.
Checking responsibility (English)
Owner of the building; operationally real estate and energy management with the design team.
Checking responsibility (German)
Eigentümer des Gebäudes; operativ Immobilien- und Energiemanagement gemeinsam mit der Fachplanung.
Check method (English)
Calculation of the annual primary energy demand against the reference building under Annex 2 and evidence under Section 41, or documentation of one of the cases in which the requirement is deemed met.
Check method (German)
Berechnung des Jahres-Primärenergiebedarfs im Vergleich zum Referenzgebäude nach Anlage 2 und Nachweis nach § 41 oder Dokumentation eines der Fälle, in denen die Anforderung als erfüllt gilt.