Kind
Approval
Due Diligence
Governance
Other
Record Keeping
Reporting
Stakeholder Engagement
Frequency
Annual
Biennial
Continuous
Event-triggered
Monthly
One-time
Other
Quarterly
Weekly
Check frequency
Annual
Biennial
Continuous
Event-triggered
Monthly
One-time
Other
Quarterly
Weekly
Rule set
Regulation-wide (no rule set)
New buildings owned by public bodies
New buildings
New buildings with more than 1 000 m² of useful floor area
Existing buildings undergoing a major renovation, and building elements retrofitted or replaced
Non-residential buildings
New non-residential buildings with more than 250 m² of total useful floor area
Existing non-residential buildings with more than 500 m² of total useful floor area undergoing a major renovation or a measure requiring a permit
New residential buildings and new covered car parks physically adjacent to buildings
New non-residential buildings and non-residential buildings undergoing a major renovation with more than five car parking spaces
New residential buildings and residential buildings undergoing a major renovation with more than three car parking spaces
Non-residential buildings with more than 20 car parking spaces
Buildings with newly installed, replaced or upgraded technical building systems
Non-residential buildings with a system rated output above 290 kW
Non-residential buildings with a system rated output above 70 kW
Building owners on construction, major renovation, sale and letting
Sellers and landlords of buildings and building units
Heating, ventilation and air-conditioning systems with a rated output above 70 kW
Systems with generators whose rated output exceeds 290 kW
Experts inspecting heating, ventilation and air-conditioning systems
Non-residential buildings for which an energy performance certificate has been issued
Owners and tenants holding certificates, renovation passports, smart readiness indicators or inspection reports
Complexity (0–5)
Business functions
Communications
Compliance
Executive
Finance
Human Resources
Legal
Operations
Other
Procurement
Product
Sales
Sustainability
Description (English)
Non-residential buildings must be equipped with automatic lighting controls in so far as this is technically and economically feasible. The controls must be suitably zoned and capable of occupancy detection. The obligation must be met by 31 December 2029 in non-residential buildings with a rated output for heating systems, air-conditioning systems, systems for combined space heating and ventilation or systems for combined air conditioning and ventilation above 70 kW. For buildings above 290 kW it already has to be met by 31 December 2027; that first stage is recorded as a separate obligation. This obligation is recorded separately from the building automation and control systems under Article 13(9) because it requires a different action and has different dates. The Directive is addressed to the Member States; the obligation only binds companies through national transposition law. Its wording requires the Member State to ensure a specific behaviour of building owners and is therefore recorded as a binding obligation of the owner. Further references: Article 13(12).
Description (German)
Nichtwohngebäude sind mit automatischen Beleuchtungssteuerungen auszustatten, soweit das technisch und wirtschaftlich realisierbar ist. Die Steuerungen müssen angemessen zoniert sein und über eine Belegungserkennung verfügen. Die Pflicht ist bis zum 31. Dezember 2029 in Nichtwohngebäuden mit einer Nennleistung für Heizungsanlagen, Klimaanlagen, kombinierte Raumheizungsanlagen und Lüftungsanlagen oder kombinierte Klima- und Lüftungsanlagen von mehr als 70 kW zu erfüllen. Für Gebäude mit mehr als 290 kW gilt sie bereits bis zum 31. Dezember 2027; diese erste Stufe ist als eigene Pflicht erfasst. Diese Pflicht ist getrennt von der Gebäudeautomation nach Artikel 13 Absatz 9 erfasst, weil sie eine andere Handlung verlangt und andere Stichtage hat. Die Richtlinie richtet sich an die Mitgliedstaaten; die Pflicht wirkt gegenüber Unternehmen erst über das nationale Umsetzungsrecht. Der Wortlaut verlangt vom Mitgliedstaat, ein bestimmtes Verhalten der Gebäudeeigentümer sicherzustellen, und ist deshalb als verbindliche Pflicht des Eigentümers erfasst. Weitere Fundstellen: Artikel 13 Absatz 12.
Affected products/services (English)
Lighting installations of the non-residential buildings concerned and their control systems.
Affected products/services (German)
Beleuchtungsanlagen der betroffenen Nichtwohngebäude und deren Steuerungen.
Checking responsibility (English)
Owner and operator of the non-residential building.
Checking responsibility (German)
Eigentümer und Betreiber des Nichtwohngebäudes.
Check method (English)
Check the building inventory for rated output and for the presence of zoned lighting controls with occupancy detection.
Check method (German)
Abgleich der Gebäudeliste mit der Anlagennennleistung und dem Vorhandensein zonierter Beleuchtungssteuerungen mit Belegungserkennung.