Emtract Ingest
API
EN
EN
DE
Dashboard
Regulations
Crawlers
Attributes
Topics
Home
/
Regulations
/
EPBD
/
Edit obligation
Edit obligation
Title (English)
Title (German)
Kind
Approval
Due Diligence
Governance
Other
Record Keeping
Reporting
Stakeholder Engagement
Frequency
Annual
Biennial
Continuous
Event-triggered
Monthly
One-time
Other
Quarterly
Weekly
Check frequency
Annual
Biennial
Continuous
Event-triggered
Monthly
One-time
Other
Quarterly
Weekly
Rule set
Regulation-wide (no rule set)
New buildings owned by public bodies
New buildings
New buildings with more than 1 000 m² of useful floor area
Existing buildings undergoing a major renovation, and building elements retrofitted or replaced
Non-residential buildings
New non-residential buildings with more than 250 m² of total useful floor area
Existing non-residential buildings with more than 500 m² of total useful floor area undergoing a major renovation or a measure requiring a permit
New residential buildings and new covered car parks physically adjacent to buildings
New non-residential buildings and non-residential buildings undergoing a major renovation with more than five car parking spaces
New residential buildings and residential buildings undergoing a major renovation with more than three car parking spaces
Non-residential buildings with more than 20 car parking spaces
Buildings with newly installed, replaced or upgraded technical building systems
Non-residential buildings with a system rated output above 290 kW
Non-residential buildings with a system rated output above 70 kW
Building owners on construction, major renovation, sale and letting
Sellers and landlords of buildings and building units
Heating, ventilation and air-conditioning systems with a rated output above 70 kW
Systems with generators whose rated output exceeds 290 kW
Experts inspecting heating, ventilation and air-conditioning systems
Non-residential buildings for which an energy performance certificate has been issued
Owners and tenants holding certificates, renovation passports, smart readiness indicators or inspection reports
Complexity (0–5)
Business functions
Communications
Compliance
Executive
Finance
Human Resources
Legal
Operations
Other
Procurement
Product
Sales
Sustainability
Description (English)
Suitable solar energy installations must be installed on all new residential buildings and on all new covered car parks physically adjacent to buildings, where technically suitable and economically and functionally feasible. Member States must ensure this by 31 December 2029. Member States set national criteria for practical implementation and possible exemptions for certain building types and may use the ground floor area instead of the useful floor area. The Directive is addressed to the Member States; the obligation only binds companies through national transposition law. Its wording requires the Member State to ensure a specific behaviour of building owners and is therefore recorded as a binding obligation of the owner.
Description (German)
Auf allen neuen Wohngebäuden und auf allen neuen überdachten Parkplätzen, die physisch an Gebäude angrenzen, sind geeignete Solarenergieanlagen zu errichten, soweit das technisch geeignet sowie wirtschaftlich und funktional realisierbar ist. Die Mitgliedstaaten haben das bis zum 31. Dezember 2029 sicherzustellen. Die Mitgliedstaaten legen national Kriterien für die praktische Umsetzung und mögliche Ausnahmen für bestimmte Gebäudearten fest und können statt der Nutzfläche die Erdgeschossfläche heranziehen. Die Richtlinie richtet sich an die Mitgliedstaaten; die Pflicht wirkt gegenüber Unternehmen erst über das nationale Umsetzungsrecht. Der Wortlaut verlangt vom Mitgliedstaat, ein bestimmtes Verhalten der Gebäudeeigentümer sicherzustellen, und ist deshalb als verbindliche Pflicht des Eigentümers erfasst.
Affected products/services (English)
Roof areas of the company’s new residential buildings and new covered car parks adjacent to buildings.
Affected products/services (German)
Dachflächen neuer Wohngebäude des Unternehmens und neue überdachte Parkplätze, die an Gebäude angrenzen.
Checking responsibility (English)
Building owner; operationally real estate and energy management together with building services engineering.
Checking responsibility (German)
Gebäudeeigentümer; operativ Immobilien- und Energiemanagement gemeinsam mit der technischen Gebäudeausrüstung.
Check method (English)
Reconciliation of the solar capacity installed per building with the nationally set criteria and documentation of the assessment of technical suitability and economic feasibility.
Check method (German)
Abgleich der je Gebäude installierten Solarleistung mit den national festgelegten Kriterien und Dokumentation der Prüfung der technischen Eignung und wirtschaftlichen Realisierbarkeit.
Withdrawn at
Cancel
Delete this obligation